1.
Chinese Journal of Medical Instrumentation ; (6): 355-359, 2023.
Article in Chinese | WPRIM | ID: wpr-982245

ABSTRACT

In recent years, proton therapy technology has developed rapidly, and the number of patients treated with proton therapy has gradually increased. However, the application of proton therapy technology was far from practical needs. Because of the shortage of resources and the high cost, proton therapy systems are not accessible and affordable for most patients. In order to change this situation, it is necessary to develop a new truly practical proton therapy system based on clinical needs. Conceptual design of a practical proton therapy system was proposed. Compared with the existing system, one feature of the newly designed system is to reduce the maximum energy of the proton beam to 175~200 MeV; another feature is the configuration of deluxe and economical treatment rooms, the deluxe room is equipped with a rotating gantry and a six-dimensional treatment bed, and the economical room is equipped with a horizontal fixed beam and a patient vertical rotating setup device. This design can not only reduce the cost of proton therapy system and equipment room construction, but also facilitate the hospital to choose the appropriate configuration, which will ultimately benefit more patients.


Subject(s)
Humans , Proton Therapy , Radiotherapy Planning, Computer-Assisted , Hospitals , Radiotherapy Dosage
2.
Chinese Journal of Radiation Oncology ; (6): 190-193, 2023.
Article in Chinese | WPRIM | ID: wpr-993173

ABSTRACT

In recent years, the issue of "reproducibility" of scientific research results has become more and more prominent. Radiobiology is a medical science that studies the biological effect of radiation on living organisms, and there is also a serious problem of "reproducibility of findings". Inaccuracy of physical dose or incomplete dosimetric reports is one of the main causes. Use of guidelines, specifications and recommendations for dosimetric measurement, such as the standardized scoring system for dosimetric reports, will help improving the standardization and accuracy of physical dose measurement in radiobiological research. In this article, multiple guidelines and recommends for improving collaboration between radiobiology and radiation physics, as well as for dose standardization of radiobiological research were evaluated, aiming to provide reference for improving the reproducibility of radiobiological research.

3.
Chinese Journal of Radiation Oncology ; (6): 42-47, 2023.
Article in Chinese | WPRIM | ID: wpr-993148

ABSTRACT

Objective:To investigate the pseudo-CT generation from cone beam CT (CBCT) by a deep learning method for the clinical need of adaptive radiotherapy.Methods:CBCT data from 74 prostate cancer patients collected by Varian On-Board Imager and their simulated positioning CT images were used for this study. The deformable registration was implemented by MIM software. And the data were randomly divided into the training set ( n=59) and test set ( n=15). U-net, Pix2PixGAN and CycleGAN were employed to learn the mapping from CBCT to simulated positioning CT. The evaluation indexes included mean absolute error (MAE), structural similarity index (SSIM) and peak signal to noise ratio (PSNR), with the deformed CT chosen as the reference. In addition, the quality of image was analyzed separately, including soft tissue resolution, image noise and artifacts, etc. Results:The MAE of images generated by U-net, Pix2PixGAN and CycleGAN were (29.4±16.1) HU, (37.1±14.4) HU and (34.3±17.3) HU, respectively. In terms of image quality, the images generated by U-net and Pix2PixGAN had excessive blur, resulting in image distortion; while the images generated by CycleGAN retained the CBCT image structure and improved the image quality.Conclusion:CycleGAN is able to effectively improve the quality of CBCT images, and has potential to be used in adaptive radiotherapy.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 653-656, 2023.
Article in Chinese | WPRIM | ID: wpr-993139

ABSTRACT

Compared with conventional radiotherapy, FLASH radiotherapy has advantages in protecting normal tissues, while the dose rate is increased by more than 100 times. If the shielding design of the treatment room is carried out according to the existing standard, the thickness and cost of the shielding wall will be significantly increased, or even hardly to meet the requirement of the standards, resultsing in the failure of the application of FLASH radiotherapy. By investigating the domestic and foreign standards and literature, this paper analyzes the challenges brought by FLASH radiotherapy technology to the shielding design of radiotherapy treatment room in China. Dose rate control standards adopted by different countries in the shielding design are emphatically compared as well. In several countries, the average dose rate under the actual treatment conditions was considered in the shielding design. In China, the method of instantaneous dose rate taking acount of occupancy factor is adopted. However, if FLASH radiotherapy technology is applied, the requirement of instantaneous dose rate will be difficult to meet. In order to improve the high dose rate radiotherapy technology such as FLASH radiotherapy, the revision of the existing standards is advised if the authorized limits are not changed. To use the average dose rate limit within a certain period of time for control, or to raise the control standard in the case of flash radiotherapy, are also avaliable.

5.
Chinese Journal of Radiological Medicine and Protection ; (12): 513-517, 2023.
Article in Chinese | WPRIM | ID: wpr-993120

ABSTRACT

Objective:To investigate a time series deep learning model for respiratory motion prediction.Methods:Eighty pieces of respiratory motion data from lung cancer patients were used in this study. They were divided into a training set and a test set at a ratio of 8∶2. The Informer deep learning network was employed to predict the respiratory motions with a latency of about 600 ms. The model performance was evaluated based on normalized root mean square errors (nRMSEs) and relative root mean square errors (rRMSEs).Results:The Informer model outperformed the conventional multilayer perceptron (MLP) and long short-term memory (LSTM) models. The Informer model yielded an average nRMSE and rRMSE of 0.270 and 0.365, respectively, at a prediction time of 423 ms, and 0.380 and 0.379, respectively, at a prediction time of 615 ms.Conclusions:The Informer model performs well in the case of a longer prediction time and has potential application value for improving the effects of the real-time tracking technology.

6.
Chinese Journal of Radiation Oncology ; (6): 1160-1163, 2022.
Article in Chinese | WPRIM | ID: wpr-956966

ABSTRACT

Objective:To observe the effect of project-based learning (PBL) in the clinical teaching of radiation physics.Methods:Thirty-two residents specializing in radiotherapy were included in the study. In the experimental group ( n=16), PBL was adopted, while traditional clinical teaching method was employed in the control group ( n=16). After the rotation, the assessment was conducted, as well as a questionnaire survey was performed, including five aspects: overall satisfaction, understanding of radiation physics knowledge, learning motivation, learning burden, and learning efficiency. Results:The assessment score in the experimental group was 86.31±5.41, which was higher than 75.28±5.91 in the control group, and the difference was statistically significant. Residents in the experimental group were satisfied with the effect of PBL.Conclusion:Compared with the traditional teaching method, PBL can improve the learning motivation, efficiency, and performance of radiotherapy residents, which is highly recognized by the residents.

7.
Chinese Journal of Radiation Oncology ; (6): 421-424, 2022.
Article in Chinese | WPRIM | ID: wpr-932685

ABSTRACT

Powered by big data and artificial intelligence, the research and clinical application of treatment planning automation for radiation therapy are rapidly growing. The application and supervision of planning automation systems necessitate careful consideration of different levels of automation, as well as the context for use. For autonomous vehicles, the levels of automation have been defined at home and abroad. Nevertheless, no such definitions exist for radiotherapy planning automation. To promote and standardize the development of radiotherapy planning automation and initiate discussion within the community, we developed this recommendation with reference to the taxonomy of driving automation for vehicles and divided the radiotherapy planning automation into six levels (level 1 to 6).

8.
Chinese Journal of Radiation Oncology ; (6): 108-111, 2022.
Article in Chinese | WPRIM | ID: wpr-932637

ABSTRACT

Non-coplanar radiotherapy is a kind of radiotherapy technology which employs multiple non-coplanar fixed fields or non-coplanar arcs. The non-coplanar field can be defined that the central axis of each field is not on the same plane, while the non-coplanar arc can be described that the trajectory formed by each arc is not on the same plane. Compared with coplanar radiotherapy, non-coplanar radiotherapy can achieve multi-angle or multi-radian irradiation, which effectively improves the focusing level of ray and is beneficial to enlarge the radiation dose of the target area between the surrounding normal tissues. Its dosimetric advantages have been proven in multiple types of tumors, such as intracranial tumors, liver cancer and lung cancer, etc. Multiple approaches can be employed to realize non-coplanar radiotherapy, which can be divided into the non-coplanar conic radiotherapy, non-coplanar conformal radiotherapy, non-coplanar intensity-modulated radiotherapy and non-coplanar volumetric modulated arc therapy according to the established sequence. In this review, the development process and principal characteristics of these implementations were summarized.

9.
Chinese Journal of Radiation Oncology ; (6): 29-34, 2022.
Article in Chinese | WPRIM | ID: wpr-932623

ABSTRACT

Objective:To introduce the clinical dosimetry commissioning methods and results of the 1.5 T MR-linac.Methods:In May, 2019, an Elekta Unity 1.5 T MR-linac was installed in Cancer Hospital, Chinese Academy of Medical Sciences and dosimetry commissioning was performed with magnetic field compatible measuring instruments. Commissioning items include absolute dose calibration, data acquisition and planning system model verification.Results:Absolute dose calibration in magnetic field should be corrected by magnetic field correction factor. The standard output dose of Unity was 87 cGy. Gamma analysis (3%/2 mm) was performed on the beam collection data and the planning system calculation data. The average pass rate of dose verification of standard field test cases was 96.41%, and the TG119 test case was 98.24%. The IROC end to end test case was 97.5%(7%/4 mm).Conclusions:The planning system model and the beam collection data have good consistency. The dose verification results of the standard field and TG119 test cases meet the general tolerance limit requirements of the AAPM TG218 report, and the verification results of the IROC end-to-end test cases meet the IROC center standards.

10.
Chinese Journal of Radiation Oncology ; (6): 924-929, 2021.
Article in Chinese | WPRIM | ID: wpr-910493

ABSTRACT

Objective:To analyze and compare the dosimetric differences based on volumetric-modulated arc therapy (VMAT), fixed field intensity-modulated radiotherapy (F_IMRT), and electron irradiation combined with VMAT (E&VMAT) in radiotherapy for breast cancer after modified mastectomy, aiming to provide reference for clinical selection of treatment plan.Methods:Ten patients with the left breast cancer who received radiotherapy after modified mastectomy were randomly selected. The target areas included chest wall and supraclavicular region, and the prescribed dose was 43.5 Gy in 15 fractions (2.9 Gy/F). Based on the Pinnacle 3 planning system, the VMAT, F_IMRT and E&VMAT plans (electron beam for chest wall, VMAT for supraclavicular area) were designed for each patient. The conformity and homogeneity of the target areas, the dose of organs at risk and treatment time were compared. Results:The VMAT plan could improve the dose distribution of the target areas. The conformity index and homogeneity index of the target dose were significantly better than those of the F_IMRT and E&VMAT plans (all P<0.05). The average dose, V 30Gy, V 20Gy, V 10Gy of the left lung in the VMAT plan were significantly better than those in the F_IMRT and E&VMAT plans (all P<0.05). The V 5Gy of the left lung in the VMAT plan was significantly better than that in the F_IMRT plan ( P<0.05). There was no statistical difference in the V 5Gy of the left lung between the VMAT and E&VMAT plans ( P>0.05). The heart, right breast and right lung of the VMAT plan could meet the clinical dose limit requirements. The treatment time of the VMAT, F_IMRT and E&VMAT plans was (326±27) s, (1 082±169) s, and (562±48) s, respectively. Conclusions:Compared with the F_IMRT and E&VMAT plans, the VMAT plan has better quality and shorter treatment time. VMAT plan has higher value in clinical application compared with the F_IMRT and E&VMAT plans.

11.
Chinese Journal of Radiation Oncology ; (6): 835-840, 2021.
Article in Chinese | WPRIM | ID: wpr-910477

ABSTRACT

Objective:To investigate the setup errors of postoperative radiotherapy immobilized with integrated cervicothoracic board (mask) system in breast cancer patients.Methods:Thirty-two breast cancer patients treated with postoperative radiotherapy immobilized with integrated cervicothoracic board (mask) system were prospectively recruited in this study. Breast/chest wall (cw) and supra/infraclavicular nodal region (sc) were irradiated with intensity-modulated radiotherapy. CBCT location verification in radiotherapy and target areas of the breast/chest wall and upper and lower collarbone were carried out, respectively. The consistency between setup errors and the position of the upper and lower target areas of 239 CBCT images was analyzed.Results:The translational setup errors of the breast/chest wall in the X-cw (left-right), Y-cw (superior-inferior), Z-cw (anterior-posterior) directions were (1.84±2.36) mm, (1.99±2.48) mm, and (1.75±1.86) mm, respectively. The translational setup errors of the supra/infraclavicular nodal region in the X-sc (left-right), Y-sc (superior-inferior), Z-sc (anterior-posterior) directions were (1.98±2.44) mm, (1.98±2.48) mm, and (1.71±1.79) mm, respectively. The differences of translational setup errors between the breast/chest wall and supra/infraclavicular nodal region in the X, Y, Z directions were (0.38±0.66) mm, (0.07±0.41) mm, and (0.45±0.92) mm, respectively. Conclusion:For the breast cancer patients treated with postoperative radiotherapy covering breast/chest wall and supra/infraclavicular nodal region, the integrated cervicothoracic board (mask) immobilization system provides good reproducibility and yields Sfew setup errors.

12.
Chinese Journal of Radiation Oncology ; (6): 797-802, 2021.
Article in Chinese | WPRIM | ID: wpr-910471

ABSTRACT

Objective:To establish an automatic planning method using volumetric-modulated arc therapy (VMAT) for primary liver cancer (PLC) radiotherapy based on predicting the feasibility dose-volume histogram (DVH) and evaluate its performance.Methods:Ten patients with PLC were randomly chosen in this retrospective study. Pinnacle Auto-Planning was used to design the VMAT automatic plan, and the feasibility DVH curve was obtained through the PlanIQ dose prediction, and the initial optimization objectives of the automatic plan were set according to the displayed feasible objectives interval. The plans were accessed according to dosimetric parameters of the planning target volume and organs at risk as well as the monitor units. All patients′ automatic plans were compared with clinically accepted manual plans by using the paired t-test. Results:There was no significant difference of the planning target volume D 2%, D 98%, D mean or homogeneity index between the automatic and manual plans ((58.55±2.81) Gy vs.(57.98±4.17) Gy, (47.15±1.58) Gy vs.(47.82±1.38) Gy, (53.14±0.95) Gy vs.(53.44±1.67) Gy and 1.15±0.05 vs. 1.14±0.07, all P>0.05). The planning target volume conformity index of the manual plan was slightly higher than that of the automatic plan (0.77±0.08 vs. 0.69±0.06, P<0.05). The mean doses of normal liver, V 30Gy, V 20Gy, V 10Gy, V 5Gy and V< 5Gy of the automatic plan were significantly better than those of the manual plan ((26.68±11.13)% vs.(28.00±10.95)%, (29.96±11.50)% vs.(31.89±11.51)%, (34.88±11.51)% vs.(38.66±11.67)%, (45.38±12.40)% vs.(50.74±13.56)%, and (628.52±191.80) cm 3vs.(563.15±188.39) cm 3, all P<0.05). The mean doses of the small intestine, the duodenum, and the heart, as well as lung V 10 of the automatic plan were significantly less than those of the manual plan ((1.83±2.17) Gy vs.(2.37±2.81) Gy, (9.15±9.36) Gy vs.(11.18±10.49) Gy, and (5.44±3.10) Gy vs.(6.25±3.26) Gy, as well as (12.70±7.08)% vs.(14.47±8.11)%, all P<0.05). Monitor units did not significantly differ between two plans ((710.67±163.72) MU vs.(707.53±155.89) MU, P>0.05). Conclusions:The automatic planning method using VMAT for PLC radiotherapy based on predicting the feasibility DVH enhances the quality for PLC plans, especially in terms of normal liver sparing. Besides, it also has advantages for the protection of the intestine, whole lung and heart.

13.
Chinese Journal of Radiation Oncology ; (6): 648-652, 2021.
Article in Chinese | WPRIM | ID: wpr-910443

ABSTRACT

By using optical surface guided radiotherapy technology, the principle of three-dimensional body surface imaging is employed to obtain body surface images in a real-time manner. By comparing with reference images, it can verify the position before treatment, and realize real-time monitoring and gated treatment during treatment. It is a non-invasive and non-radiation technology, which is mainly applied in the treatment of intracranial, head and neck, chest and abdomen, breast, extremities and pediatric tumors. The research progresses consist of four aspects including less body surface markers, less restraint fixation, safer collision prediction and more accurate real-time tracking.

14.
Chinese Journal of Radiation Oncology ; (6): 587-591, 2021.
Article in Chinese | WPRIM | ID: wpr-910432

ABSTRACT

Objective:To design a drum-shaped applicator through Monte Carlo simulation for breast intraoperative radiotherapy.Methods:Applicator designing process is as follows: first, determined the shape of the applicator based on the geometric characteristics of the breast tumor bed closed to the chest wall; second, calculated the scattering angle and dose rate of the electron beam after passing through a series of scattering foils of different thicknesses to determine the thickness of the scattering foil; thrid, modeled the layer according to the applicator′s geometric characteristics where modulator located, and designed the modulator through the relationship between the geometric characteristics of the layer and the surface dose of the applicator. EGSnrc/BEAMnrc and EGS4/DOSXYZ were employed to model the head of the Mobetron, the layer, the applicator, and to calculate the dose distributions.Results:The applicator has two components. The upper component is a 3cm-diametre cylindrical collimator with 0.5cm wall made of 0.3cm steel and 0.2cm water equivalent material (WEM), a 0.13cm-foil made of tansgen. The lower component is a 4cm-diametre drum made of 0.2cm WEM and a 0.14cm maximum thickness hill-shaped modulator made of steel. When the energy of electron beam was 12MeV, the dose rate was about 90.44 cGy/min, and the depth of the 50% isodose curve was 1cm.Conclusion:The applicator is successfully designed, and can obtain a drum-shaped dose distribution.

15.
Chinese Journal of Radiation Oncology ; (6): 258-261, 2021.
Article in Chinese | WPRIM | ID: wpr-884553

ABSTRACT

Objective:To evaluate the application of visual feedback coaching method, which is embedded in an optical surface monitoring system, in deep inspiration breath holding during the radiotherapy in left breast cancer patients after breast-conserving surgery.Methods:Thirty patients with left breast cancer, who were scheduled to receive the whole breast radiotherapy after breast-conserving surgery, met the requirements of deep inspiration breath holding after respiratory coaching with the visual feedback coaching module in the optical surface monitoring system. Active breathing control equipment was used to control breath-holding state and CT simulation was performed. During treatment, optical surface monitoring system was used to guide radiotherapy. All patients were randomly divided into two groups. In group A ( n=15), visual feedback respiratory training method was utilized and not employed in group B ( n=15). In group A, the visual feedback coaching bar of the optical surface monitoring system was implemented, while audio interactive method was employed to guide patients to hold their breath. Real-time data of optical body surface monitoring were used to compare the interfraction reproducibility and intrafraction stability of breath holding fraction between two groups. Besides, the number of breath holding and treatment time per fraction were also compared. GraphPad prism 6.0 software was used for data processing and mapping, and SPSS 21.0 software was used for analyzing mean value and normality testing. Results:Compared with the control group, the reproducibility in the experiment group was reduced from 1.5 mm to 0.7 mm, the stability was reduced from 1.1 mm to 0.8 mm, the mean number of breath holding required per fraction was decreased from 4.6 to 2.4, the mean beam-on time per fraction from 336 s to 235 s, and the treatment time per fraction was shortened from 847 s to 602 s (all P<0.05), respectively. Conclusions:The application of visual feedback coaching method can improve the reproducibility and stability of breath holding during radiotherapy for left breast cancer, and it can also effectively reduce the number of breath holding and shorten the treatment time per fraction.

16.
Chinese Journal of Radiation Oncology ; (6): 963-967, 2020.
Article in Chinese | WPRIM | ID: wpr-868712

ABSTRACT

Objective:The Lorentz force produced by magnetic field deflects the paths of secondary electrons. The X-ray beam dosimetry characteristics of the magnetic resonance accelerator (MR-Linac) are different from conventional accelerators. The purpose of this study was to measure and analyze the X-ray beam dosimetry characteristics of 1.5T MR-Linac.Methods:In May 2019, our hospital installed a Unity 1.5T MR-Linac and measured it with magnetic field compatible tools. The measurement indexes include: surface dose, maximum dose point depth, beam quality, off-axis dose profile center, beam symmetry, penumbra width, output changes of different gantry angles.Results:The average surface dose was 40.48%, and the average maximum dose depth was 1.25 cm. The center of the 10 cm×10 cm beam field was offset by 1.47 mm to the x2 side and 0.3 mm to the y2 side. The x-axis symmetry was 101.33%, and the penumbra width on both sides was 6.86 mm and 7.14 mm, respectively. The y-axis symmetry was 100.85%, and the penumbra width on both sides was 5.92 mm and 5.95 mm, respectively. The maximum deviation of output dose with different gantry angles reached 1.50%. Conclusions:The surface dose of MR-Linac tend to be consistent, and the depth of the maximum dose point became shallower. The off-axis in the x-axis direction was shifted to the x2 side, which resulting in worse symmetry and penumbra asymmetry. The output dose at different angles has obvious variation and needs correction.

17.
Chinese Journal of Radiation Oncology ; (6): 919-924, 2020.
Article in Chinese | WPRIM | ID: wpr-868707

ABSTRACT

Accurate delineation of breast tumor bed and its target volume is of great importance in the planning of postoperative radiotherapy. Registration of different medical images and radiotherapy-oriented CT images can provide more comprehensive information, which can assist radiation oncologists to delineate the target contours. Image registration methods can be divided into the rigid and non-rigid types according to geometrical transformation property. Due to complex and non-rigid deformation of soft tissues, it is difficult to utilize rigid registration to strictly align the non-rigid structures. Non-rigid registration tends to achieve better results. In this article, the application of two types of registration methods in target volume delineation of breast tumor bed was reviewed and the existing problems in clinical practice were analyzed and the research direction of non-rigid registration was prospected.

18.
Chinese Journal of Radiation Oncology ; (6): 461-465, 2020.
Article in Chinese | WPRIM | ID: wpr-868618

ABSTRACT

Objective:To evaluate the effect of fast cone beam CT (CBCT) scan mode on image quality and registration results, and to establish the scanning pre-settings for fast CBCT.Methods:Three scanning modes were utilized to the CBCT phantom, and the registration accuracy and image quality were quantitatively evaluated. The correlation and consistency of measurement results under different scanning modes were further verified by 278 sets of CBCT data from 33 clinical tumor patients.Results:The maximum deviation between the measurement results of three scanning models and the actual value was 0.70 mm (0.51 mm on average). The measurement results of the same location were consistent among three scanning modes (0.00 mm). For the uniformity, the results of the normal mode were the best (3.62% on average), followed by the fast 1 mode (3.90% on average) and the fast 2 mode (4.84% on average). For the noise, the results of the normal mode were the best (15.69 on average), followed by the fast 2 mode (17.23 on average) and the fast 1 mode (21.74 on average). Regarding the high contrast resolution, the measurement results of three scanning modes were consistent (at least 3 pairs could be distinguished). For the low contrast resolution, the results of the fast 1 mode were the best (1.69 on average), followed by the normal mode (2.10 on average), and the fast 2 mode (2.31 on average). For the geometric accuracy, the measurement results of the three scanning modes were basically consistent with a mean deviation of 0.05 mm. The correlation of the measurement results between normal mode and fast 1 mode was the highest in clinical cases ( R2>0.90, P<0.01) with a high degree of consistency (95% consistency limit of the above two scanning modes< 1 mm threshold). Conclusion:Compared with the normal mode, the fast 1 mode can yield equivalent image quality, consistent registration results, faster scanning speed and lower scanning dose. Therefore, the fast 1 mode is recommended as the scan mode in clinical practice.

19.
Chinese Journal of Radiation Oncology ; (6): 278-282, 2020.
Article in Chinese | WPRIM | ID: wpr-868595

ABSTRACT

Objective:To establish the basic procedures of the application of optical surface monitoring system (OSMS) in the deep inspiration breath hold (DIBH) radiotherapy for patients with left sided breast cancer and compare the performance of OSMS and cone-beam CT (CBCT) in the determination of the set-up errors of DIBH radiotherapy for patients with left sided breast cancer.Methods:Twenty patients with left sided breast cancer received DIBH radiotherapy. Through the registration of CBCT images with the planning CT images, and the registration of OSMS radiography images with the outer contour of the body surface, translational set-up errors and rotational errors were determined along the lateral-medial ( Rx), superior-inferior ( Ry) and anterior-posterior ( Rz) directions. Pearson correlation analysis was performed to evaluate the correlation of the set-up errors determined by two methods, and Bland- Altman plot analysis was used to assess the coincidence of these two methods. Results:Two methods were positively correlated. The Rz volume was 0.84, 0.74 and 0.84 in the x, y and z directions, and 0.65, 0.41 and 0.54 in the Rx, Ry and Rz directions, respectively (all P<0.01). The 95% CI of agreement were within preset 5 mm tolerance (-0.37-0.42cm, -0.39-0.41cm, -0.29-0.49cm ) in x, y and z directions for two methods. The 95% CI of agreement were within preset 3 ° tolerance -2.9°-1.4°, -2.6°-1.4°, -2.4°-2.5°in Rx, Ry and Rz directions for two methods. The system errors of 20 patients with left sided breast cancer receiving DIBH radiotherapy were <0.18cm and the random errors were <0.24cm. Conclusions:OSMS is equivalent to CBCT in the determination and stimulation of set-up errors for patients with left sided breast cancer receiving DIBH radiotherapy. The combination of CBCT and OSMS is a safe and reliable method.

20.
Chinese Journal of Radiation Oncology ; (6): 197-202, 2020.
Article in Chinese | WPRIM | ID: wpr-868579

ABSTRACT

Objective In this study,the deep learning algorithm and the commercial planning system were integrated to establish and validate an automatic segmentation platform for clinical target volume (CTV) and organs at risk (OARs) in breast cancer patients.Methods A total of 400 patients with left and right breast cancer receiving radiotherapy after breast-conserving surgery in Cancer Hospital CAMS were enrolled in this study.A deep residual convolutional neural network was used to train CTV and OARs segmentation models.An end-to-end deep learning-based automatic segmentation platform (DLAS) was established.The accuracy of the DLAS platform delineation was verified using 42 left breast cancer and 40 right breast cancer patients.The overall Dice Similarity Coefficient (DSC) and the average Hausdorff Distance (AHD) were calculated.The relationship between the relative layer position and the DSC value of each layer (DSC_s) was calculated and analyzed layer-by-layer.Results The mean overall DSC and AHD of global CTV in left/right breast cancer patients were 0.87/0.88 and 9.38/8.71 mm.The average overall DSC and AHD range for all OARs in left/right breast cancer patients were ranged from 0.86 to 0.97 and 0.89 to 9.38 mm.The layer-by-layer analysis of CTV and OARs reached 0.90 or above,indicating that the doctors were only required to make slight or no modification,and the DSC_s ≥ 0.9 of CTV automatic delineation accounted for approximately 44.7% of the layers.The automatic delineation range for OARs was 50.9%-89.6%.For DSC_s < 0.7,the DSC_s values of CTV and the regions of interest other than the spinal cord were significantly decreased in the boundary regions on both sides (layer positions 0-0.2,and 0.8-1.0),and the level of decrease toward the edge was more pronounced.The spinal cord was delineated in a full-scale manner,and no significant decrease in DSC_s was observed in a particular area.Conclusions The end-to-end automatic segmentation platform based on deep learning can integrate the breast cancer segmentation model and achieve excellent automatic segmentation effect.In the boundary areas on both sides of the superior and inferior directions,the consistency of the delineation decreases more obviously,which needs to be further improved.